S10362-11-025C
Abstract: No abstract text available
Text: MPPC multi-pixel photon counter S10362-11 series S10362-11-025U /-050U/-100U S10362-11-025C /-050C/-100C S10362-11-025P /-050P/-100P New type of Si photon-counting device, Active area: 1 x 1 mm The MPPC is a new type of photon-counting device made up of multiple APD (avalanche photodiode) pixels operated in Geiger
|
Original
|
PDF
|
S10362-11
S10362-11-025U
/-050U/-100U
S10362-11-025C
/-050C/-100C
S10362-11-025P
/-050P/-100P
SE-171
KAPD1022E05
S10362-11-025C
|
Untitled
Abstract: No abstract text available
Text: Detectors Silicon Geiger Mode Avalanche Photodiode Description The SAP500-Series is based on a “reach-through” structure for excellent quantum efficiency, extremely low noise and bulk dark current and high gain. They are intended for ultra-low light level applications. This APD can be used
|
Original
|
PDF
|
SAP500-Series
|
"Constant fraction discriminator"
Abstract: mppc 001 S10362-33-050C S10362-33 Constant fraction discriminator geiger apd Light Dependent Resistor Constant fraction timing discriminator geiger tube geiger
Text: T E C H N I C A L I N F O R M ATION ® T ECHNICA L INF OR M AT I ON The MPPC Multi-Pixel Photon Counter is a new type of photon-counting device made up of multiple APD (avalanche photodiode) pixels operated in Geiger mode. The MPPC is essentially an opto-semiconductor device with excellent photon-counting capability and which also possesses great advantages such as low voltage operation and insensitivity to magnetic fields.
|
Original
|
PDF
|
SE-171
KAPD9003E02
"Constant fraction discriminator"
mppc 001
S10362-33-050C
S10362-33
Constant fraction discriminator
geiger apd
Light Dependent Resistor
Constant fraction timing discriminator
geiger tube
geiger
|
CAM32X32B-GMA-0
Abstract: 0/ladar microlens array
Text: PRODUCT SUMMARY 32 x 32 Geiger-mode Avalanche Photodiode GmAPD Camera The Princeton Lightwave 32 x 32 Geiger-mode avalanche photodiode (GmAPD) camera is a turn-key system containing a single-photon imaging sensor designed for three-dimensional laser radar imaging
|
Original
|
PDF
|
|
NE-2H
Abstract: geiger tube Geiger geiger counter XFORMER High Voltage Generator for Flash and Geiger Tubes geiger tubes 4093 1N4005 2n4403
Text: High Voltage Generator for Flash and Geiger Tubes Here is a 700 volt power supply for powering a Geiger tube or charging a capacitor in a flash unit. The circuit uses a 1:1 telephone isolation transformer typically used in modems. The voltage is determined
|
Original
|
PDF
|
100uA
1N4005
MPS-A42
2N4403
2N4401
NE-2H
geiger tube
Geiger
geiger counter
XFORMER
High Voltage Generator for Flash and Geiger Tubes
geiger tubes
4093
1N4005
2n4403
|
transistor RCA 467
Abstract: ota ca 3080 RCA 3080 rca CA3080 RCA 467 rca cmos book rca cmos handbook IEEE J. Solid State Circuits, SC "rca application note" rca 1967
Text: R. L. Geiger and E. Sánchez-Sinencio, "Active Filter Design Using Operational Transconductance Amplifiers: A Tutorial," IEEE Circuits and Devices Magazine, Vol. 1, pp.20-32, March 1985. Active Filter Design Using Operational Transconductance Amplifiers: A Tutorial
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Detectors Silicon Geiger Mode Avalanche Photodiode Description The SAP500-Series is based on a “reach-through” structure for excellent quantum efficiency, extremely low noise and bulk dark current and high gain. They are intended for ultra-low light level applications. This APD can be used
|
Original
|
PDF
|
SAP500-Series
|
Untitled
Abstract: No abstract text available
Text: Features: Solid state sensor technology, long life and precision Broad band of combustible gas detection Sensitivity as low as 5 ppm Adjustable sensitivity Audible "Geiger counter" signal LED Leak Intensity Lights Automatic warm up Cordless operation Flexible 16" stainless probe for hard to
|
Original
|
PDF
|
TIF8900
TIF8801
TIF8806A
TIF8803A
TIF8806B
ATP-7038
527690RED
TIF8801:
TIF8803A:
TIF8805
|
information applikation mikroelektronik
Abstract: mikroelektronik applikation mikroelektronik zf Mikroelektronik Information Applikation
Text: Die multimediale Informationsgesellschaft wird Realität Start in neue Dimensionen Der Autor: Dipl.-Ing. GERHARD GEIGER ist bei Infineon Technologies für „Communication System Solutions“ verantwortlich. Vor rund 15 Jahren steckte die multimediale Kommunikation,
|
Original
|
PDF
|
|
Geiger-muller
Abstract: AN3757 Geiger geiger tube Geiger-Mueller geiger tubes MAX4162 APP3757 radiation tube radiation DETECTOR CIRCUITS
Text: Maxim > App Notes > AMPLIFIER AND COMPARATOR CIRCUITS POWER-SUPPLY CIRCUITS Keywords: high voltage, boost converter, multistage voltage multiplier, Geiger-Muller tube Mar 22, 2006 APPLICATION NOTE 3757 Bias Supply Powers Low-Power Geiger-Mueller Tube Abstract: A high-voltage bias supply for a Geiger-Mueller tube features small size and low power consumption.
|
Original
|
PDF
|
com/an3757
MAX4162:
AN3757,
APP3757,
Appnote3757,
Geiger-muller
AN3757
Geiger
geiger tube
Geiger-Mueller
geiger tubes
MAX4162
APP3757
radiation tube
radiation DETECTOR CIRCUITS
|
Geiger-muller
Abstract: 60Co
Text: Datenservice Selbstverlöschendes Geiger-Müller-Zählrohr mit Glimmerfenster zur Messung von y-Strahlung im Bereich 7.10-3.70nA/kg 10-4.1R/h und ß-Strahlung Füllung: Ne, Ar, (Halogen) Fenster: Material Dicke eff.0 Fläche 0,635 cm2 Katode: Material
|
Original
|
PDF
|
70nA/kg
11I11I
Geiger-muller
60Co
|
S10931
Abstract: S10362-33-050C geiger apd S10362-33 Hamamatsu avalanche diode Si apd photodiode Photon mppc 01 geiger counter tip350
Text: MPPC multi-pixel photon Counter S10362-33 series S10362-33 series S10931 series S10931 series New type of Si photon-counting device, Active area: 3 x 3 mm The MPPC is a new type of photon-counting device made up of multiple APD (avalanche photodiode) pixels operated in Geiger
|
Original
|
PDF
|
S10362-33
S10931
SE-171
KAPD1023E02
S10362-33-050C
geiger apd
Hamamatsu avalanche diode
Si apd photodiode
Photon
mppc 01
geiger counter
tip350
|
1bw smd
Abstract: S10362-33-050C S10362-33 S10931 smd 1bw geiger apd S1036 1bw smd transistor smd 1bw 56 S10931-050P
Text: MPPC multi-pixel photon Counter S10362-33 series S10362-33 series S10931 series S10931 series New type of Si photon-counting device, Active area: 3 x 3 mm The MPPC is a new type of photon-counting device made up of multiple APD (avalanche photodiode) pixels operated in Geiger
|
Original
|
PDF
|
S10362-33
S10931
SE-171
KAPD1023E05
1bw smd
S10362-33-050C
smd 1bw
geiger apd
S1036
1bw smd transistor
smd 1bw 56
S10931-050P
|
18529
Abstract: Scans-0017320 geiger tube Geiger-muller philips 18529
Text: PHILIPS Halogen quenched gamma RADIATION COUNTER TUBE for high Intensity measurement up to 1000 r/h TUBE COMPTEUR DE RADIATION gamma avec halO£ene_ comme gaz de coupure pour la mesure d'intensité elevée jusqu'à 1000 r/h GEIGER-MÜLLER-ZÏHLROHR mit Löschung mittels Halogen zur
|
OCR Scan
|
PDF
|
|
|
1S537
Abstract: Scans-0017320 xray philips Geiger-muller tube 1j5
Text: PHILIPS 18537 Halogen quenched X-RAY COUNTER TUBE with mica end window TUBE COMPTEUR DE RAYONS X à découpage par halogène avec fenêtre frontale de mica GEIGER-MÜLLER-ZÄHLROHR FÜR RÖNTGENSTRAHLUNG mit Löschung mittels Halogen und mit frontalem Glimmerfenster
|
OCR Scan
|
PDF
|
1S537
1S537
Scans-0017320
xray philips
Geiger-muller
tube 1j5
|
Untitled
Abstract: No abstract text available
Text: Series High Voltage 4-10 High Voltage 4-10 Hochspannung 4-10 Coaxial high-voltage connector with a two-pin bayonet locking system for general purpose high-voltage applications, espe cially for Geiger-Miiller counter tubes where rapid connection and disconnection is required.
|
OCR Scan
|
PDF
|
D-84526
|
philips 18504
Abstract: geiger tube 18504 18504 TUBE geiger tube Geiger-muller 18504 28Chrom Geiger CM314 Scans-0017318
Text: PHILIPS Î18504 R A D I A T I O N C O U N T L R T U B E self quen c h i n g , w i t h m i c a window} C O M P T E U R D E R A D I A T I O N (auto-coupeur, avec fenêtre de mica GEIGER-LIÜLLER-ZÄHLROHR (selbstlöschend, mit Glimmerfenster) App l i c a t i o n : M e a s u r i n g o f alpha, be t a , g a m m a a n d n e u t r o n
|
OCR Scan
|
PDF
|
|
et 455
Abstract: Philips schema compteur radiation tube Scans-0017319
Text: PHILIPS Halogen-quenched RADIATION COUNTER TUBE with mica end window for measurement of gamma and beta radiation TUBE COMPTEUR DE RADIATION à coupure par halogène et avec fenêtre de mica pour la mesure de radiations gamma et bêta GEIGER-MtîLLER-ZÄHLROHR mit Löschung mittels Halogen und
|
OCR Scan
|
PDF
|
5x1010
et 455
Philips schema
compteur
radiation tube
Scans-0017319
|
Philips 18505
Abstract: geiger tube Geiger-muller BEL100 radiation tube alpha 600 handbook Philips Geiger 28Chrom geiger counter 18505 geiger mueller
Text: r-18505 P H ILIP S RADIATION COUNTER TUBE, self quenching, with mica window, for.the measurement of alpha, beta and gamma radiation COMPTEUR DE RADIATION, auto-coupeur, avec fenêtre de mica, pour la mesure _de rayonnements alpha, beta et gamma. GEIGER MÜLLER ZAHLROHR, selbstlöschend, mit Glimmerfenster,
|
OCR Scan
|
PDF
|
7R06247
Philips 18505
geiger tube
Geiger-muller
BEL100
radiation tube
alpha 600 handbook
Philips Geiger
28Chrom
geiger counter 18505
geiger mueller
|
geiger counter 18506
Abstract: philips 18506 Philips Geiger geiger tube Geiger-muller geiger 1bs0s 28Chrom 18506 Geiger-Mueller
Text: PHILIPS 18506 RADIATION COUNTER TUBE, self quenching, with mica window, for the measurement of alpha, beta and gamma radiation COMPTEUR DE RADIATION, auto-coupeur, avec fenêtre de mica, pour la mesure de rayonnements alpha, beta et gamma GEIGER HÜLLER ZAHLROHR, selbstlöschend, mit Glimmerfenster,
|
OCR Scan
|
PDF
|
|
Geiger-muller
Abstract: geiger radiation tube Scans-0017318
Text: 18510 PHILIPS Halogen quenched BETA RADIATION LIQUID FLOW COUNTER TUBJÏ TUBE COMPTEUR DE RADIATION BÊTA D'UN COURANT LIQUIDE a découpage par halogène GEIGER-MÜLLER-ZÄKLROHR FÜR BETASTRAHLUNG VON FLÜSSIGKEITS STRÖMEN mit Löschung mittels Halogen
|
OCR Scan
|
PDF
|
14max
1S51G
Geiger-muller
geiger
radiation tube
Scans-0017318
|
Geiger-muller
Abstract: geiger counter 18545 geiger tube 18545 18545A Scans-0017320 philips 18545 i8545
Text: PHILIPS Halogen quenched GAMMA RADIATION COUNTER TUBE TUBE COMPTEUR DE RADIATION GAMMA a découpage par halogène GEIGER-MÜLLER-ZSHLROHR FÜR GAMMASTRAHLUNG mit Löschung mittels Halogen Filling : Ne, Ar and halogen quenching agent Remplissage: Ne, Ar et halogene comme gaz de coupure
|
OCR Scan
|
PDF
|
|
Philips schema
Abstract: 18520 geiger 18520 Geiger-muller geiger tube Scans-0017319 philips 18520
Text: Halogen-quenched .RADIATION COUNTER TUBE for measurement of gamma radiation TUBE COMPTEUR DE RADIATION à coupure par halogène pour la mesure„de radiation gamma GEIGER-MÜLLER-ZÄHLROHR mit Löschung mittels Halogen zur Messung von Gammastrahlung Filling
|
OCR Scan
|
PDF
|
|
18550
Abstract: philips 18550 geiger tube geiger Scans-0017320 radiation tube geiger counter observer
Text: PHILIPS ri855Ö Thin wall type halogen quenched RADIATION COUNTER TUBE for beta and gamma radiation COMPTEUR DE RADIATION avec paroi since et avec halogène comme gaz de coupure pour radiations bêta et gamma GEIGER-MULLER-ZÄHLROHR mit dünner Wand und Halogenlöschsubstanz für Beta- und Gammastrahlung
|
OCR Scan
|
PDF
|
1S55G
18550
philips 18550
geiger tube
geiger
Scans-0017320
radiation tube
geiger counter
observer
|