VHR-3N
Abstract: BVH-21T JST VHR-8N connector xhp 4 XHP-4
Text: Connector Data Sheet RS Stock No: 424396 Connector Kit 7 Contains: JST Input Connector: VHR-3N x 1 JST Output Connector: VHR-8N x 1 JST Crimps: BVH-21T x 11, BXH-001T x 8 Output Housing: XHP-4 x 2
|
Original
|
PDF
|
BVH-21T
BXH-001T
VHR-3N
JST VHR-8N
connector
xhp 4
XHP-4
|
JST BXH-001T-P0.6
Abstract: BVH-21T-P1 BVH-21T JST VHR-8N XHP-2 VHR-8N
Text: Connector Data Sheet RS Stock No. 381835 Connector Kit E3 Contains: JST Input Connector: VHR -3N x 1 JST Output Connector: VHR-8N x 1 plus XHP-2 x 1 JST Crimps: BVH-21T-P1.1 x 11 plus BXH-001T-P0.6 x 2
|
Original
|
PDF
|
BVH-21T-P1
BXH-001T-P0
JST BXH-001T-P0.6
BVH-21T
JST VHR-8N
XHP-2
VHR-8N
|
VHR-3N
Abstract: XHP-4 BVH-21T BXH-001T connector XHP-2 xhp 4
Text: Connector Data Sheet RS Stock No: 424368 Connector Kit 8 Contains: JST Input Connector: VHR-3N x 1 JST Output Connector: VHR-8N x 1 JST Crimps: BVH-21T x 11, BXH-001T x 8 Output Housing: XHP-2 x 1, XHP-4 x 1
|
Original
|
PDF
|
BVH-21T
BXH-001T
VHR-3N
XHP-4
connector
XHP-2
xhp 4
|
M63M83-04
Abstract: No abstract text available
Text: CABLE OUTPUT CABLE FOR BACKLIGHT INVERTER Output Cable No.1 Output Cable No.2 Output Cable No. 3 JST Housing: Connector: JST Housing: BHR-02VS-1 Connector: SM02 4.0 B-BHS1-TB Length: 200mm stripped and tinned JST Housing: BHR-03VS-1 Connector: SM02(8.0)B-BHS1-TB
|
Original
|
PDF
|
BHR-02VS-1
200mm
BHR-03VS-1
BHR-04VS-1
500mm
M63M83-04
M63M83-04
|
Untitled
Abstract: No abstract text available
Text: DESCRIPTIDN/ECD NO. REV. RELEASED 305±6.0 1 I" :U 77 BLACK -J NOTES 1. HOUSING XHP-3 JST 2. CONTACT SXH-001T-PO.6 (JST) PIN 1 ~ THIRD ANGLE PROJECTION DRAWN BY DIMENSIONS ARE IN MILLIMETERS TOLERANCE UNLESS OTHERWISE SPECIFIED 1 PL+I- 4.0 JKL J. K. DATE
|
Original
|
PDF
|
SXH-001T-PO
BXC-12379/1CON
|
ccfl inverter
Abstract: inverter ccfl ccfl inverter INV ccfl circuit INVERTER FOR CCFL LAMP Lamp Inverter OA-0012-8045D
Text: Type Cold Cathode Lamp Inverter Drive module 12VDC input Connector system JST XHP-2 Part No. INV 5 OA-0012-8045D TR1 + C1 R1 CCFL output Connector system JST XHP-3 T1 R2 L1 C2 TR2 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA Dual Output suitable for CCFL length:
|
Original
|
PDF
|
12VDC
OA-0012-8045D)
12VDC
ccfl inverter
inverter ccfl
ccfl inverter INV
ccfl circuit
INVERTER FOR CCFL LAMP
Lamp Inverter
OA-0012-8045D
|
Untitled
Abstract: No abstract text available
Text: DESCRIPTIDN/ECD NO. REV. RELEASED 265±6.0 I" :1] "1_, I' 47 REDIPINK REDIPINK - NOTES 1. HOUSING XHP-5 JST 2. CONTACT SXH-001T-PO.6 (JST) PIN 2 3 4 5 ~ THIRD ANGLE PROJECTION DRAWN BY DIMENSIONS ARE IN MILLIMETERS TOLERANCE UNLESS OTHERWISE SPECIFIED 1 PL+I- 4.0
|
Original
|
PDF
|
SXH-001T-PO
BXC-12379/0CON-01
|
Untitled
Abstract: No abstract text available
Text: DESCRIPTIDN/ECD NO. REV. RELEASED SOS±6.0 I" J~~ /I ~ [] f~ WHITE 71 -l NOTES 1. HOUSING XHP-3 JST 2. CONTACT SXH-001T-PO.6 (JST) PIN 2 3 ~ THIRD ANGLE PROJECTION DRAWN BY DIMENSIONS ARE IN MILLIMETERS TOLERANCE UNLESS OTHERWISE SPECIFIED 1 PL+I- 4.0 JKL
|
Original
|
PDF
|
SXH-001T-PO
BXC-12379/0CON-02
|
power converter board
Abstract: converter 24vdc to 12vdc 24VDC molex 43025-0400 43025-0400 connector 12VDC 24v backlight inverter XHP-8 inverter board backlight
Text: Power Converter board P/N 416013900-3 The power converter board P/N 416013900-3 designs for providing 12VDC output to panel and controller and 24VDC to panel backlight inverter. CNB1 – +24VDC, max 8A Power input Connector used : JST S8B-XH-A, Mating type : JST XHP-8 or compatible
|
Original
|
PDF
|
12VDC
24VDC
24VDC,
460mm
power converter board
converter 24vdc to 12vdc
molex 43025-0400
43025-0400
connector 12VDC
24v backlight inverter
XHP-8
inverter board backlight
|
JST XHP-3
Abstract: ccfl inverter INVERTER FOR CCFL LAMP Suitable for Inverter ccfl inverter INV
Text: Type Cold Cathode Lamp Inverter Drive module 5VDC input Connector system JST XHP-2 Part No. INV 10 O1- 100-020K CCFL output Connector system JST XHP-3 - + TR1 R1 C1 T1 L1 R2 C2 TR2 L70 x W20 x H15 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA
|
Original
|
PDF
|
100-020K)
JST XHP-3
ccfl inverter
INVERTER FOR CCFL LAMP
Suitable for Inverter
ccfl inverter INV
|
JST XHP-3
Abstract: 0505D xhp 4 OA-6012-0505D ccfl inverter connector XHP3 XHP-2
Text: Type Cold Cathode Lamp Inverter Drive module 12VDC input Connector system JST XHP-2 Part No. INV 8 OA-6012-0505D CCFL output Connector system JST XHP-3 - + TR1 L1 C1 R1 T1 R2 C3 C4 TR2 L75 x W25 x H15 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA
|
Original
|
PDF
|
12VDC
OA-6012-0505D)
12VDC
JST XHP-3
0505D
xhp 4
OA-6012-0505D
ccfl inverter connector
XHP3
XHP-2
|
JST XHP-3
Abstract: JST VL ccfl inverter INV JST XHP-3 connector XHP-3 INVERTER FOR CCFL LAMP Suitable for Inverter 6 ccfl inverter ccfl 12vdc lamp inverter circuit CCFL Lamp Inverter
Text: Type Cold Cathode Lamp Inverter Drive module 12VDC input Connector system JST XHP-2 - Part No. INV 6 OA-6012-0504D CCFL output Connector system JST XHP-3 + TR1 C1 R1 T1 R2 L1 C2 C3 TR2 L70 x W20 x H15 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA
|
Original
|
PDF
|
12VDC
OA-6012-0504D)
12VDC
JST XHP-3
JST VL
ccfl inverter INV
JST XHP-3 connector
XHP-3
INVERTER FOR CCFL LAMP
Suitable for Inverter
6 ccfl inverter
ccfl 12vdc lamp inverter circuit
CCFL Lamp Inverter
|
OA-0012-8045A
Abstract: 2 ccfl inverter 700V ccfl circuit ccfl inverter inverter ccfl INVERTER FOR CCFL LAMP jst connector JST XHP-3 connector Suitable for Inverter
Text: Type Cold Cathode Lamp Inverter Drive module Part No. INV 9 OA-0012-8045A _ 5VDC input Connector system JST XHP-2 TR1 + C1 CCFL output Connector system JST XHP-3 T1 R2 L1 C2 TR2 L 49 x W 18 x H 13 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA
|
Original
|
PDF
|
OA-0012-8045A)
OA-0012-8045A
2 ccfl inverter
700V
ccfl circuit
ccfl inverter
inverter ccfl
INVERTER FOR CCFL LAMP
jst connector
JST XHP-3 connector
Suitable for Inverter
|
OA-0012-8045B
Abstract: ccfl inverter 2 ccfl inverter inverter ccfl INVERTER FOR CCFL LAMP jst connector ccfl inverter connector Suitable for Inverter
Text: Type Cold Cathode Lamp Inverter Drive module Part No. INV 11 OA-0012-8045B _ 5VDC input Connector system JST XHP-2 TR1 + C1 CCFL output Connector system JST XHP-3 T1 R2 L1 C2 TR2 L 49 x W 18 x H 13 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA
|
Original
|
PDF
|
OA-0012-8045B)
OA-0012-8045B
ccfl inverter
2 ccfl inverter
inverter ccfl
INVERTER FOR CCFL LAMP
jst connector
ccfl inverter connector
Suitable for Inverter
|
|
H7605305
Abstract: 51021-0500 W16878 CONN1 xhp 4 erg inc 2pin
Text: H7605305 JST # XHP-5 “Conn 2” Molex # 51021-0500 “Conn 1” 1 1 5 5 1 4 JST # XHP-4 “Conn 3” 12.0[305] ± .25 [6,4] Pin Assignments Conn1 Conn2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 2 Conn3 Pin 1 Pin 1 Pin 2 Pin 3 #26 AWG Wire, MIL STD W16878 PROPRIETARY
|
Original
|
PDF
|
H7605305
W16878
H7605305
51021-0500
W16878
CONN1
xhp 4
erg inc
2pin
|
H5205305
Abstract: CONN1 xhp 4 erg inc CONN2 XHP-4 51021-0800
Text: H5205305 JST # XHP-5 “Conn 2” Molex # 51021-0800 “Conn 1” 1 1 5 8 1 4 JST # XHP-4 “Conn 3” 12.0[305] ± .25 [6,4] Pin Assignments Conn1 Conn2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 2 Conn3 Pin 1 Pin 1 Pin 2 Pin 3 #26 AWG Wire, MIL STD W16878
|
Original
|
PDF
|
H5205305
W16878
H5205305
CONN1
xhp 4
erg inc
CONN2
XHP-4
51021-0800
|
H7506305
Abstract: CONN2 51021-0800 XHP-4 H7506 erg inc
Text: H7506305 JST # XHP-5 “Conn 2” Molex # 51021-0800 “Conn 1” 1 1 5 8 1 4 JST # XHP-4 “Conn 3” 12.0[305] ± .25 [6,4] Pin Assignments Conn1 Conn2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 2 Conn3 Pin 1 Pin 1 Pin 3 Pin 3 Pin 4 Conn2 pin 5 jumper to Conn3 pin 2
|
Original
|
PDF
|
H7506305
W16878
H7506305
CONN2
51021-0800
XHP-4
H7506
erg inc
|
UL1007 AWG24
Abstract: AWG24 XHP-5 cable tie INVERTER Wire ul1007 12v inverter 12v inverter circuit Inverter application note inverter circuit
Text: SOLDER END CABLE TIE WITH P/N TAG CABLE TIE HS1 5mm CABLE LENGTH = 300mm +10/-5mm WIRE: HS1 PIN2: UL1007 AWG24 RED OTHERS: UL1007 AWG24 WHITE CONTROLLER SIDE HS1 GND +12V BLCTRL BVR_WIP BVR_A 1 2 3 4 5 WHITE RED WHITE WHITE WHITE XHP-5 JST DIGITAL VIEW LTD.
|
Original
|
PDF
|
300mm
10/-5mm
UL1007
AWG24
CABLE\C6058300
UL1007 AWG24
XHP-5
cable tie
INVERTER
Wire ul1007
12v inverter
12v inverter circuit
Inverter application note
inverter circuit
|
CXA-0190
Abstract: CXA-0240 PHR-5 XhP-4 SI-8390D-02 CXA-01 JST XHP-4 xhp 4
Text: NOTE FOR VERSION CHANGE: CABLE TIE WITH P/N TAG 00 -> 01 HS2,3 HS1 - CORRECTED CONNECTORS REFERENCE NAME - CHANGED HS2.5 TO HS3.2 WIRE LENGTH TO 60mm - STATED HS1 MUST USE JST CABLE LENGTH = 300mm +10/-5mm WIRE: HS2 PIN 2: UL1007 AWG24 RED OTHERS: UL1007 AWG24 WHITE
|
Original
|
PDF
|
300mm
10/-5mm
UL1007
AWG24
CXA-0240
CXA-0190
CXA-0231
SI-8390D-02
CXA-0240
PHR-5
XhP-4
CXA-01
JST XHP-4
xhp 4
|
Untitled
Abstract: No abstract text available
Text: REV. DESCRIPTION/ECO NO. RELEASED PIN 1 2 3 4 5 NOTES 1. HOUSING XHP-5 JST 2. CONTACT SXH-001T-P0.6 (JST) DIMENSIONS ARE IN MILLIMETERS METRIC - { ) — r " T - THIRD ANGLE PROJECTION DRAWN BY L. WENGSTROM TOLERANCE UNLESS OTHERWISE SPECIFIED 1 PL + /- 4.0
|
OCR Scan
|
PDF
|
SXH-001T-P0
BXC-12379/OCON-OI
RED/PINK24
|
SXH-001T-P06
Abstract: UL3239 SXH-001T-P0
Text: REV. DESCRIPTION/ECO NO. RELEASED DATE 6/ 12/01 3.0 REF. PIN 1 2 3 NOTES 1. HOUSING XHP-3 JST 2. CONTACT SXH-001T-P0.6 (JST) METRIC DIM EN S IO N S AR E IN M ILLIM ETE R S TO LER AN C E UNLESS OTHERW ISE SPEC IFIED TH IR D AN G LE PROJECTION DRAWN BY L. WENGSTROM
|
OCR Scan
|
PDF
|
SXH-001T-P0
BXC-12379/OCON-Q2
SXH-001T-P06
UL3239
|
Untitled
Abstract: No abstract text available
Text: REV. DESCRIPTION/ECO NO. RELEASED DATE 2/14/03 308.0 PIN 1 2 3 4 NOTES: 1. HOUSING XHP-4 JST 2. CONTACT SXH-001T-P0.6 (JST) METRIC e3THIRD ANGLE PROJECTION DRAWN BY D IM E N S IO N S A R E IN M IL L IM E T E R S TOLERANCE UNLESS OTHERWISE SPECIFIED 1 PL
|
OCR Scan
|
PDF
|
SXH-001T-P0
|
SXH-001T-P0.6 drawing
Abstract: No abstract text available
Text: REV. DESCRIPTION/ECO NO. DATE RELEASED 2/14/03 ADD RoHS NOTE 2/13/07 8.00 PIN 1 2 3 4 WIRE TYPE AWG COLOR UL 3613 24 WHT NC NC 24 WHT UL 3613 JKL PART NO.: BXC-10585 METRIC NOTES: 1. HOUSING XHP-4 JST 2. CONTACT SXH-001T-P0.6 (JST) 3. RoHS COMPLIANCE (CONTACT JKL FOR RoHS LOT IDENTIFICATION)
|
OCR Scan
|
PDF
|
BXC-10585
SXH-001T-P0
SXH-001T-P0.6 drawing
|
SXH-001T-P06
Abstract: JST SXH-001T-P0.6 connector sxh001tp06 SXH-001T-P0.6 drawing XHP-3 JST XHP-3 connector UL1007
Text: REV. DESCRIPTION/ECO NO. RELEASED DATE 3/23/05 5 REF. NOTES 1. HOUSING XHP-3 JST 2. CONTACT SXH-001T-P0.6 (JST) PIN 1 2 3 METRIC DIM E N S IO N S AR E IN M ILLIM ETE R S TO LER AN C E UNLESS OTHERW ISE SPEC IFIED TH IR D AN G LE PR OJECTION DRAW N BY 1 PL +/- 4.0
|
OCR Scan
|
PDF
|
SXH-001T-P0
UL1007
BXC-12379/ICON
SXH-001T-P06
JST SXH-001T-P0.6 connector
sxh001tp06
SXH-001T-P0.6 drawing
XHP-3
JST XHP-3 connector
|