Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    S8981 Search Results

    SF Impression Pixel

    S8981 Price and Stock

    Vishay Dale RWR84S8981DRBSL

    RES 8.98K OHM 7W 0.5% WW AXIAL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey RWR84S8981DRBSL Bulk 100
    • 1 -
    • 10 -
    • 100 $32.1477
    • 1000 $32.1477
    • 10000 $32.1477
    Buy Now

    Vishay Dale RWR74S8981DSB12

    RES 8.98K OHM 5W 0.5% WW AXIAL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey RWR74S8981DSB12 Bulk 100
    • 1 -
    • 10 -
    • 100 $14.105
    • 1000 $14.105
    • 10000 $14.105
    Buy Now

    Vishay Dale RWR84S8981DRB12

    RES 8.98K OHM 7W 0.5% WW AXIAL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey RWR84S8981DRB12 Bulk 100
    • 1 -
    • 10 -
    • 100 $25.8375
    • 1000 $25.8375
    • 10000 $25.8375
    Buy Now

    Vishay Dale RWR84S8981DRRSL

    RES 8.98K OHM 7W 0.5% WW AXIAL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey RWR84S8981DRRSL Reel 100
    • 1 -
    • 10 -
    • 100 $30.9625
    • 1000 $30.9625
    • 10000 $30.9625
    Buy Now

    Vishay Dale RWR74S8981DSRSL

    RES 8.98K OHM 5W 0.5% WW AXIAL
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey RWR74S8981DSRSL Reel 100
    • 1 -
    • 10 -
    • 100 $15.9375
    • 1000 $15.9375
    • 10000 $15.9375
    Buy Now

    S8981 Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    S8981 Hamamatsu IC IMAGE SENSOR B/W CCD 1500X1000 Original PDF
    S8981-02 Hamamatsu Front-illuminated FFT-CCDs for X-ray imaging Original PDF

    S8981 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    fw300

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8980, S8981-02 S8980 S8981-02 S898102 S8981 SE-171 fw300

    dental sensor

    Abstract: S1500 S1502 S8980 S8981-02 CCD 22 pin fax
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8980, S8981-02C S8980 S8981-02C SE-171 KMPD1084E03 dental sensor S1500 S1502 S8981-02 CCD 22 pin fax

    Untitled

    Abstract: No abstract text available
    Text: S8981P Linear ICs Crosspoint Switch Circuit status Military/High-RelN Nom. Supp V 5.0 Minimum Operating Temp (øC)0 Maximum Operating Temp (øC)70 Package StyleDIP Mounting StyleT Pinout Equivalence Code40-23 # Pins40 Ckt. (Pinout) NumberLN04000023 DescriptionCrosspoint Switch for voice or data


    Original
    PDF S8981P Code40-23 Pins40 NumberLN04000023

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    PDF S8980, S8981 S8980 S8981 S7362-01 SE-171

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    PDF S8980, S8981 S8980 S8980 S8981 S7362-01 SE-171

    S8981

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8980, S8981-02C S8980 S8981-02C S898hone: SE-171 S8981

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    PDF S8980, S8981 S8980 S8981 S7362-01 SE-171

    dental sensor

    Abstract: S1500 S1502 S7362-01 S8980 S8981 image sensor x-ray dental x-ray sensor
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    PDF S8980, S8981 S8980 S8980 S8981 S7362-01 SE-171 dental sensor S1500 S1502 S7362-01 image sensor x-ray dental x-ray sensor

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8980, S8981-02 S8980 S8981-02 S898102 S8981 SE-171

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8980, S8981-02 S8980 S8981-02 S898102 S8981 SE-171

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making S8980


    Original
    PDF S8980, S8981 S8980 S8980 S8981 S7362-01 SE-171

    dental x-ray sensor

    Abstract: S8981-02 S1500 S1502 S8980 S8981 S1503
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02 Front-illuminated FFT-CCDs for X-ray imaging S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8980, S8981-02 S8980 S8981-02 S898102 S8981 SE-171 dental x-ray sensor S1500 S1502 S1503

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8980, S8981-02C Front-illuminated FFT-CCDs for X-ray imaging The S8980 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8980 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8980, S8981-02C S8980 S8981-02C S898hone: SE-171

    Untitled

    Abstract: No abstract text available
    Text: S8981D Linear ICs Crosspoint Switch Circuit status Military/High-RelN Nom. Supp V 5.0 Minimum Operating Temp (øC)0 Maximum Operating Temp (øC)70 Package StyleDIP Mounting StyleT Pinout Equivalence Code40-23 # Pins40 Ckt. (Pinout) NumberLN04000023 DescriptionDigital Time/Space Crosspoint Switch


    Original
    PDF S8981D Code40-23 Pins40 NumberLN04000023

    pin out mdr 50 pin CONNECTOR

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171 pin out mdr 50 pin CONNECTOR

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02C Front-illuminated FFT-CCDs for X-ray imaging The S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8984, S8985-02C S8984 S8985-02C SE-171 KMPD1085E05

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02C Front-illuminated FFT-CCDs for X-ray imaging The S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8984, S8985-02C S8984 S8985-02C SE-171 KMPD1085E04

    MDM 6600

    Abstract: mt 1389 de 2061 D nikko AR9344 bosch AL 1115 CV denso alternator 7805/3A bosch al 1450 dv CATERPILLAR 207-1560 ba 4918
    Text: No. 9800-OERF-007 Replaces • Remplace • Substituye No. 9800-OERF-005 Dixie Electric Ltd. OEM CROSS REFERENCE GUIDE DE RÉFÉRENCE GUÍA DE REFERENCIA 2007 Index • Índice AGCO .1


    Original
    PDF 9800-OERF-007 9800-OERF-005 MDM 6600 mt 1389 de 2061 D nikko AR9344 bosch AL 1115 CV denso alternator 7805/3A bosch al 1450 dv CATERPILLAR 207-1560 ba 4918

    sensor x-ray

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8982, S10127 Front-illuminated FFT-CCDs for X-ray imaging S8982 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8982 has 1.5 mega 1500 x 1000 pixels each of which is 20 × 20 µm. S8982 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode.


    Original
    PDF S8982, S10127 S8982 S10127 S8981-02 SE-171 sensor x-ray

    dental image sensor x-ray

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171 dental image sensor x-ray

    Untitled

    Abstract: No abstract text available
    Text: Digital Urne/Space Crosspoint Switch •> G o u l d AMI Semiconductors Preliminary Data Sheet S8981 Features General Description □ ST-BUS com patible □ 4-Line x 32-Channel Inputs □ 4-Line x 32-Channel O utputs □ 128 Ports N on-Blocking Switch □ Single Power Supply + 5V


    OCR Scan
    PDF S8981 32-Channel S6802

    mek6802d3 processor

    Abstract: s6802 s3507a "digital switching system" DS35-07A
    Text: AM I S8981 STANDARD PRODUCTS Digital Tim e/Space Crosspoint Sw itch February 1993 Features General Description This VLSI ISO-CMOS device is designed for swit­ ching PCM-encoded voice or data, under micro­ processor control, in a modern digital exchange,


    OCR Scan
    PDF S8981 32-Channel mek6802d3 processor s6802 s3507a "digital switching system" DS35-07A

    DS8980J

    Abstract: DS8980N DS8981J DS8981N J18A N18A DS8981 DS8980
    Text: Display Drivers DS898Q, S8981 High Voltage 7-Segment Latches/Decoders/Drivers General Description Features T h e D S8980, S8981 c ir c u its are c u rre n t- p r o g r a m m a b le s e g m e n t-ra tio e d , 7-se g m e n t gas dis c h a rg e tu b e d is p la y


    OCR Scan
    PDF DS898Q, DS8981 DS8980, DS8981. DS8980J DS8980N DS8981J DS8981N J18A N18A DS8980